一、             Choosing Graphite Electrode
 Please choose the suitable graphite electrodes grade and diameter according to the capacity of furnace and the matched transformer.(Attch 1)
 
Nominal Diameter
Regular Power
Impregnate (HD
High Power
Ultra High Power
mm
Inch
Current-Carrying Capacity(A)
Current DensityA/cm2
Current-Carrying Capacity (A)
Current DensityA/cm2
Current-Carrying Capacity(A)
Current DensityA/cm2
Current-Carrying Capacity(A)
Current DensityA/cm2
75
3
1000~1400
22-31
1300-2000
29-45
 
 
 
 
100
4
1500~2400
19-31
1800-3000
22-37
 
 
 
 
130
5
2200~3400
17-26
2800-4200
21-31
 
 
 
 
150
6
3000~4500
16-25
4000-5000
22-28
 
 
 
 
175
7
3800~5100
16-21
3900-6800
16-28
 
 
 
 
200
8
5000~6900
15-21
4800-9000
15-28
5500-9000
18-25
 
 
225
9
6000~8000
15-20
6400-9700
16-24
6500-10000
18-25
 
 
250
10
7000~10000
14-20
8000-12000
16-24
8000-13000
18-25
 
 
300
12
10000~13000
14-18
11000-16000
15-22
13000-17400
17-24
15000-22000
20-30
350
14
13500~18000
14-18
15000-22000
15-22
17400-24000
17-24
20000-30000
20-30
400
16
18000~23500
14-18
20000-28000
15-22
21000-31000
16-24
25000-40000
19-30
450
18
22000~27000
13-17
24000-34000
15-21
25000-40000
15-24
32000-45000
19-27
500
20
25000~32000
13-16
28000-42000
13-20
30000-48000
15-24
38000-55000
18-27
Remake: the operating current ranges in table 2 are for AC EAF, DC EAF or LF can run at a reasonable higher current level with the electrode.
二、二、Handling and stacking of the electrode
1、Operate carefully when lift and move the electrodes so as to avoid drop and damage caused by the inclining of the electrode.
2、To keep the end face of the electrode and the thread in the socket in a good status, never hook into the sockets on both side of the electrode with metal hooks when moving the electrodes.
3、Carefully lift up and down when load and unload the case with nipples so as to prevent the nipples from clicking against each other and cause damages to the thread of the nipples thereof.
4、Don’t put the electrodes and nipples directly onto the grand, put them onto wooden bars or metal stands instead, collision or sand contamination must be avoided. Don’t take the packing materials away when the electrode and nipples are not going be used. Dust and contaminations to the threads must be avoided.
5、Electrode must be stacked in order in a warehouse; both ends of an electrode stack must be blocked safely so as to avoid collapsing. The electrodes stacks should be lower than 2 meters high.
6、Electrodes in the stacks must be protected away from rains and heavy humidity, wet electrode must be dried before being loaded onto the furnace so as to reduce the risks of cracking and over high oxidization when operation.
7、Nipples must be away from high temperature to prevent the pitch plugs from melting.